WNDR3700v1 upgrade problems

Report problems and success stories with Gargoyle on various hardware platforms.

Moderator: Moderators

Post Reply
ed1023
Posts: 3
Joined: Fri Mar 30, 2012 3:23 am

WNDR3700v1 upgrade problems

Post by ed1023 »

Good day all I have been using gargoyle 1.5.3. When I up graded my WNDR3700v1 for the stock image to gargoyle 1.5.3 every thing went fine. When I tryed to upgrade the image to 1.5.4 the up grade screen came up and just sat there spining. I left it alone for over an hour a cople times. One time the update screen spinner froze and the other time it just kept spinning. Any ideas on how I could get the new version of gargoyle on my router. Or how to get the factory image back (same thing happens here) so that I can up load the new version of gargoyle. I have looked in the forums but did not find any thing. If some one knows of a post that might be helpfull please point me to it.

ed1023
Posts: 3
Joined: Fri Mar 30, 2012 3:23 am

Re: WNDR3700v1 upgrade problems

Post by ed1023 »

Like always when I ask for help I find an answer.
I was able to restore the original factory image using this forum post at dd-wrt
http://www.dd-wrt.com/phpBB2/viewtopic.php?t=79802
Then I was able to upload the newest Gargoyle. If any one has an idea why the upgrade was just spinning please let me know.
Thanks

User avatar
DoesItMatter
Moderator
Posts: 1373
Joined: Thu May 21, 2009 3:56 pm

Re: WNDR3700v1 upgrade problems

Post by DoesItMatter »

I've seen this happen occasionally to other members and myself.

Not sure what the issue is but I think its related to some settings
in Gargoyle that don't allow the upgrade to go correctly.

Future upgrades - do the following:

1) Fresh reboot of router
2) Fresh backup of config
3) Restore to Defaults on router! (important)
4) As soon as you are back into the GUI - reset the password,
login, and immediately upgrade firmware - don't change anything
5) After firmware update & reboot - restore old config file
** May not always work with old config - if any issues with this
re-configure from defaults, don't use your old config file **

This should almost always allow you to upgrade properly.
:twisted: Soylent Green Is People! :twisted:
2x Asus RT-N16 = Asus 3.0.0.4.374.43 Merlin
2x Buffalo WZR-HP-G300NH V1 A0D0 = Gargoyle 1.9.x / LEDE 17.01.x
2x Engenius - ESR900 Stock 1.4.0 / OpenWRT Trunk 49400